No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: Transfer output using control output.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function
E2E2-X10Y2 5M
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Fitting materials: Stainless steel (SUS304).
Count: 1 .
Accessories: Description, None;
Material, --;
Count, -- .
Applicable sensor (mounting pitch on sensor side): E3X-DA-S/MDA,
E3X-NA, E3C-LDA, E2C-EDA, E4C-UDA.
Page: Dimensions, 13. Appearance: Unshielded, M18.
Sensing distance: 10 mm [6 to 10 mm *].
Output Model: DC 3-wire NPN.
Operation mode: NC.
Fluororesin-coated Capacitive.
Sensor with Sensitivity Adjuster.
Excellent resistance against chemicals and oil with fluororesin,
coated case.
Distance adjustment according to the sensing object using the,
sensitivity adjuster. Cable Specifications: Fire-retardant, Robot cable.
Cable connection direction: Straight.
Cable diameter: 6.0 mm dia.
No. of cable cores: 2.
Cable core cross sectional area: 0.5 mm.
Cable length: 5 m.
AC.
Minimum order: 5.
UL-listed: Yes.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202.
E2E2-X10Y2 5M Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E2E2-X10Y2 5M&select=5