Sensor-less Monitoring of Standstill for,
Machines with Long Inertia.
Standstill is monitored by the motor''s back electromotive force (BEMF) signal.
Features a "Standard Configuration", allowing immediate use,
without sensitivity adjustment.
"User Configuration" also available for fine-tuning of sensitivity.
Detailed LED indications enable easy fault diagnosis.
Safety Category 4 (EN954-1), PLe(ISO13849-1),
SIL 3 (IEC/EN 62061) certified
E3JK-T61 2M Appearance: M30.
Sensing distance: 20 mm.
Connection method: Pre-wired Models(2 m) .
Cable specifications: PVC (oil-resistant).
Polarity: Yes.
Operation mode : NO .
Pin arrangement: --.
Applicable connector code: --.
Your Search for Proximity Sensors.
Starts with the World-leading.
Performance and Quality of the E2E.
Standard Sensors for detecting ferrous metals.
Wide array of variations. Ideal for a variety of applications.
Models with different frequencies are also available to prevent,
mutual interference.
Superior environment resistance with standard cable made of oil,
resistant PVC and sensing surface made of material that resists,
cutting oil.
Useful to help prevent disconnection.
Cable protector provided as a standard feature. Ideal for monitoring 3-phase power supplies.
for industrial facilities and equipment.
Monitor overvoltages, undervoltages, phase sequence, and,
phase loss for three-phase 3-wire or 4-wire power supplies with,
just one Unit.
Switch setting for 3-phase 3-wire or 3-phase 4-wire power,
supply.
Two SPDT output relays, 6 A at 250 VAC (resistive load).
Output overvoltages and undervoltages using separate relays.
World-wide power specifications supported by one Unit,
(switchable).
Output status can be monitored using LED indicator. Configuration: Covered Power Supplies.
Input voltage: 100 to 240 VAC (free) (80 to 370 VDC *).
S8JX-G15005@@:Switchable between 100 to 120 VAC and 200 to 240 VAC.
(DC power cannot be input.).
Power ratings: 100 W.
Output voltage: 12 V.
Output current: 8.5 A.
Built-in fan: No.
Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 48 V).
Easy Mounting: Front-mounted type, DIN rail-mounted type are available.
Screw-mount at the top. (except 300-/600-W models).
Safety standards: UL 508/60950-1, cUL CSA C22.2 No. 107.1,
cUR CSA C22.2 No. 60950-1.
EN 50178 (= VDE 0160) Over voltage.
category III.
EN 60950-1 (= VDE 0805 Teil 1).
EMC: Conforms to EN 61204-3.
(EMI:EN55011 ClassA).
Input conditions: The input voltage range of 15-W, 35-W,
50-W, 100-W, and 150-W models has,
been increased to 80 to 370 VDC (EC Directives and safety standards do not apply.).
E3JK-T61 2M Operation manual / Instructions / Catalog download link: