Sensor type: Limited distance reflective.
Sensing distance: 10 to 50 mm.
Connection method: pre-wired.
Model: PNP output.
A new generation in sensing performance.
Simplicity.
Simple selection.
Simple installation.
One family for all.
All standard applications covered.
A wide variety of models.
Models designed for special applications.
Non-stop detection.
High quality and reliability.
High EMC protection
E3S-AT41-L 2M
High light immunity.
Robust and waterproof housing. Release Key Type: Standard (metal).
Wiring method: Connector.
Solenoid voltage/Indicator: 24VDC (without indicator).
Lock and release type: Solenoid lock Mechanical release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 4-contact Model,
Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank @.
Conduit size (See Note.): M20.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames.
The plastic material makes the Slide Key suitable,
for lightweight doors. Number of notches: 2 notches.
Output: SPDT.
Reset method: Automatic.
Key release position: Left.
Separate Construction with Cylindrical.
16-dia. Body.
Short mounting depth, less than 28.5 mm below panel.
Wide range of switching capacity from standard to microload.
Oil-resistant IP65 models. Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 4.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.
E3S-AT41-L 2M Operation manual / Instructions / Catalog download link: /searchDownload.html?Search=E3S-AT41-L 2M&select=5