Ratings: Standard load; 4 A at 30 VDC.
Cable: VCTF cable *2.
Actuator: Roller plunger.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material
E3X-DAG41-S 2M
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Appearance: Round/Half-guard type LED lighting,
(without Voltage Reduction Unit) A22L-H.
Output: SPST-NC.
Lighting: LED.
Operating voltage: 24 VAC/VDC.
Operation: Alternate operation (self-holding).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit.
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Standard function model: detection of under voltage.
Appearance: ADR shell.
Open circuit: voltage, no voltage, DC circuit breaker.
Rated voltage: AC110V.
Rated frequency: 50/60Hz.
Voltage adjustment range: 60-65-70-75-80-85-90-95-100V (9 shunt).
Time hopping: timing; 0.1-0.2-0.4-0.6-0.8-1.0-1.2-1.4-1.6-1.8-2.0s (11 shunt).
Control power supply: and input common.
Rated consumption VA:7VA.
Control output: 1C, 1A closed 110V 15A1000 L/R=0ms times (DC);
Open 110V 1A DC 1000 (L/R=25ms).
Display: display resolution 1V (display range: 50-130V).
Automatic experiment: there.
Quality: about 1kg.
External: Mount Searl N1.5.
Digital voltage relay series.
K2VU-H/K2VA-H type, large range of adjustment shunt,
Easy to coordinate digital VR.
And the automatic tester with convenient for relay testing.
Measurable voltage value.
The reliability can be improved by monitoring the function at any time.
The forced action of the experimental switch can be easily recognized.
Exterior dimension based on DIN standard,
The depth is only the size of the 88.5mm (terminal except).
E3X-DAG41-S 2M Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E3X-DAG41-S 2M&select=5