Actuator: One-way roller arm lever (vertical).
Conduit size: 2-conduit; M20.
Built-in switch mechanism: 3NC (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement
E3ZM-LS64H 5M
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Classification: Low-cost Models.
Description: Low-cost thermocouple.
Temperature range (See note 3.): 0°C to 400°C.
Element type: K (CA) J (IC).
Conductor type: Grounded type.
Class: 2 (0.75).
Protective tubing material: SUS304.
Terminal type: Exposed lead wires.
Page: 20.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Sensor type and wiring: 3-wire DC NPN/2-wire DC 3-4.
Actuator wiring: Actuator wiring 1-4.
No. of ports: 4.
No. of I/O: 8.
Simple Wiring of Sensor Actuators.
Greatly reduce wiring in combination with the Smartclick XS5.
Insert the connector and turn 1/8 of a turn to lock the connectors.
Higher rated current to enable output applications.
Use previous M12 screw connectors. Release key type: Trapped key *1.
Indicator: Green.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 2NC/1NO+2NC/1NO.
Conduit opening: G1/2.
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns.
Standard gold-clad contacts enable use with ordinary loads,
and microloads.
Models with trapped keys prevent workers from being locked,
in hazardous work areas.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection.
E3ZM-LS64H 5M Operation manual / Instructions / Catalog download link: