Actuator: Roller lever (resin lever, resin roller).
Conduit size: 2-conduit; M20.
Built-in switch mechanism: 3NC (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability
E5CN-HR2 AC100-240
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Supply voltage: 24, 100 to 120, 200 to 230 VAC; 12, 24, 48, 100 to 110, 125 VDC.
Time-limit contact: 4PDT.
Long-time range model(0.1 min to 10 h).
Miniature Timer with Multiple Time Ranges,
and Multiple Operating Modes.
UL listed when used with a Push-In Plus Terminal Block Socket.
Conforms to CSA, CE Marking, LR, and CCC.
Black design with power supply terminals on top and contact output,
terminals on bottom.
Standard multiple operating modes and multiple time ranges.
Pin configuration compatible with MY Power Relay.
Minimizes stock. Ontology: program type.
Size: 48 x 96mm.
Type: basic type (1 input).
Control mode: standard control, heating and cooling control.
Output (control / transfer) points: 2 points (current + current).
Output (SUB) points: 4 points.
Event entry point: 2.
Serial communication: -.
New high speed, high precision digital regulator (Cheng Xuxing)!
Can be set up to 32 kinds of procedures.
1 units can be coordinated to run up to 4 channels.
High speed acquisition of 50ms.
With CX-Thermo on the computer easily set. Ratings: Standard load;0.1 A at 125 VAC, 0.1 A at 30 VDC.
Cable: VCTF oil-resistant cable *1.
Actuator: Roller plunger.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)
E5CN-HR2 AC100-240 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E5CN-HR2 AC100-240&select=5