Appearance: Shielded, M12.
Sensing distance: 3 mm.
Output configuration: DC 2-wire (polarity).
Operation mode: NO.
Proximity Sensor Ideal for the Food and Beverage Industry. Model: P7S/P7SA, pages 20 and 21, Front-mounting.
Approx: 59 g.
Number of pins: 14 pins.
A Wide Variety of Square and,
Round Sockets in Front-mounting,
and Back-mounting Models,
Models available with finger protection
E5CN-HR2MD-500 AC/DC24
Hold-down Clips and Socket Bridges for PYF Sockets,
are also available.
New screwless models available. Type: Reverse wiring.
Cable length L: 1.0 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch. Unit classification: CJ1 Special I/O Units.
Product name: ProcessInput Units,
(Isolated-type Thermocouple Input Units).
Input points: 2 inputs.
Signal range selection:
Set separately for each input.
Signal range: Thermocouple:
B, E, J, K, L, N, R, S, T, U,
WRe5-26, PLII DC voltage: ±100 mV.
Conversion speed (resolution): Conversion,
speed: 10 ms/2 inputs, Resolution: 1/64,000.
Accuracy at ambient temperature of 25°C:
Standard accuracy: ±0.05% of F.S.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.18A; 24V, 0.06A.
Standards: UC1, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four input channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage).
All inputs are isolated. Ratings: Standard load; 4 A at 30 VDC.
Cable: VCTF cable *2.
Actuator: Center roller lever.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)
E5CN-HR2MD-500 AC/DC24 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E5CN-HR2MD-500 AC/DC24&select=5