Specification: three phase 400V.
Power: 0.75KW.
Maximum output voltage: three phase input voltage.
Rated voltage, frequency: three-phase power supply 380 ~ 50/60Hz, 480V.
Cooling way: natural wind cooling.
Weight: 1.2kg.
Open loop vector control mode of low speed and high torque, rich control function and convenient distribution management network function,
Set in one of the inverter --3G3MZ.
3G3MZ series inverter for the application of frequency control and development
E6C3-CWZ3XH 300P/R 1M
Humanized design and advanced management technology, as well as OMRON a simple style of modeling, feature rich style,
Combined with the latest technical needs of users, so that it has a noble lineage and the most close to the market elements.
Covers the special features of the fan pump class, open loop vector function,
Built in noise filter and a variety of network bus,
3G3MZ will be your most economical and the most perfect choice. Rated voltage: 230 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2100 r/min; 60 Hz, 2200 r/min.
Maximum flow rate: 50 Hz, 0.9 m3/min; 60 Hz, 1.0 m3/min.
Maximum static pressure: 50 Hz, 43 Pa; 60 Hz, 42 Pa.
Noise: 50 Hz, 42 dB; 60 Hz, 43 dB.
Weight: Approx. 1120 g.
Comprehensive Lineup of Single,
Double, and Triple Axial Fans with,
Easy One-step Mounting.
Mounts in a square cutout and conceals the hole-cut to,
simplify installation work.
Cover can be set to open either upward or downward for,
convenience in confined spaces.
Enhanced accessories (finger guard, filter, plug cord,
mounting screws).
Optional Replacement Filter and Vent Attachment.
The lineup includes Single, Double, and Triple Box Fans,
with eight models with plastic blades and eight models with,
metal blades. Number of beams: 48.
Protective height: 960mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
E6C3-CWZ3XH 300P/R 1M Operation manual / Instructions / Catalog download link: