Sensing method: Retro-reflective Sensors.
Appearance: Vertical.
Connection method: Pre-wired.
Sensing distance: 7 m.
Functions: Timer Self Diagnosis Turbo External Diagnosis.
Model: PNP output.
Ordering Information.
Built-in Amplifier Photoelectric Sensors. Function name: 3 phase 400V.
Power: 5.5KW.
Rated output voltage: 3 phase, 380 ~ 480V (the output voltage can not exceed the input voltage)
EE-SA401-P2
Built in brake unit (brake resistance needs to be matched).
Weight: 3.5KG.
Dimension (w * h) 260mm *:140.
Outline dimension (deep):155mm.
Mechanical automation concept.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication.
Driver programming function.
Current vector control.
High starting torque: 0.5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H. Standard function model: detection of under voltage.
Appearance: ADR shell.
Open circuit: voltage, no voltage, DC circuit breaker.
Rated voltage: AC110V.
Rated frequency: 50/60Hz.
Voltage adjustment range: 60-65-70-75-80-85-90-95-100V (9 shunt).
Time hopping: timing; 0.1-0.2-0.4-0.6-0.8-1.0-1.2-1.4-1.6-1.8-2.0s (11 shunt).
Control power supply: and input common.
Rated consumption VA:7VA.
Control output: 1C, 1A closed 110V 15A1000 L/R=0ms times (DC);
Open 110V 1A DC 1000 (L/R=25ms).
Display: display resolution 1V (display range: 50-130V).
Automatic experiment: there.
Quality: about 1kg.
External: Mount Searl N1.5.
Digital voltage relay series.
K2VU-H/K2VA-H type, large range of adjustment shunt,
Easy to coordinate digital VR.
And the automatic tester with convenient for relay testing.
Measurable voltage value.
The reliability can be improved by monitoring the function at any time.
The forced action of the experimental switch can be easily recognized.
Exterior dimension based on DIN standard,
The depth is only the size of the 88.5mm (terminal except). Output: SPDT.
Lighting: LED (with built-in reduced-voltage lighting function).
Operating voltage: 100/110 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1.
EE-SA401-P2 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=EE-SA401-P2&select=5