OMRON
Home >> Products >> OMRON >> CS1G/CS1H/CS1D/CS1W PLC >> CS1 series PLC CPU high function unit >> 3G8F7-CLK53-E

3G8F7-CLK53-E

OMRON 3G8F7-CLK53-E Manual And Instructions
3G8F7-CLK53-E datasheetPDF datasheet
3G8F7-CLK53-E OPERATION MANUAL
3G8F7-CLK53-E SYSTEM MANUAL

OMRON 3G8F7-CLK53-E Product information and technical parameters:
Brand: OMRON
Name:
Model: 3G8F7-CLK53-E
Connection type: PCI, wired CLK.
Description: Controller link PCI board with support software.

Unit type: CS1 Special I/O Units.
Name: CompoBus/S Master Unit.
Specifications: Communications,
functions, Remote I/O communications;
No. of I/O points, 256 max.
(128 inputs and 128 outputs), 128 max.
(64 inputs and 64 outputs);
Max. Units mountable per CPU Unit, 95, 96.
No. of unit numbers allocated: 2; 1 3G8F7-CLK53-E.
Current consumption: 5V, 0.15A; 26V, --.
Standards: U, C, CE.
CompoBus/S is a high-speed I/O bus 3G8F7-CLK53-E Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Resistance Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: Pt100, JPt100.
Conversion speed (resolution):
250 ms/4 inputs.
Externa connection: Removable erminal block 3G8F7-CLK53-E.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.25A; 26V, --.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value 3G8F7-CLK53-E.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools. Unit type: CS1 Special analog I/O Units.
Product name: Analog I/O Units.
Specifications: I/O points,
4 inputs, 4 outputs;
Signal range selection,
Set separately for each input;
Signal range, 1 to 5 V, 0 to 5 V,
0 to 110 V, -10 V to 10 V, 4 to 20 mA;
Resolution, 1/4000 ;
Conversion speed, 1 s/point 3G8F7-CLK53-E.
Externa connection, Removable erminal block.
Current consumption: 5V, 0.20A; 26V, 0.20A.
Standards: UC1, N, L, CE.
For Various Analog I/Os.
Anaalog Input Units for converting,
analog input signals into binary data 3G8F7-CLK53-E.
Analog Output Units for converting ,
binary data into analog output signals.


...More relevant models >>>>