OMRON
Home >> Products >> OMRON >> CS1G/CS1H/CS1D/CS1W PLC >> CS1 series PLC CPU high function unit >> 3G8F7-SLK21-E

3G8F7-SLK21-E

OMRON 3G8F7-SLK21-E Manual And Instructions
3G8F7-SLK21-E datasheetPDF datasheet
3G8F7-SLK21-E SYSTEM MANUAL
3G8F7-SLK21-E SYSTEM MANUAL

OMRON 3G8F7-SLK21-E Product information and technical parameters:
Brand: OMRON
Name:
Model: 3G8F7-SLK21-E
Coaxial.

Connection type: PCI, wired CLK.
Description: Controller link PCI board with support software.Name: I/O Interface Unit.
Specifications: Applicable systems,
Duplex CPU, Single I/O Expansion System,
or Single CPU System;
Duplexing, Not supported;
Online Replacement, Not supported;
Mounting Backplane,Expansion Backplane;
Connecting Cable,
Long-distance Connecting Cable 3G8F7-SLK21-E.
Current consumption: 5V system, 0 3G8F7-SLK21-E23A;
26V system, --.
Standards: U, C, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables. Product name: CS1 CPU Backplane.
Specifications: For CS-series,
Unit only Note: C200H series,
Units cannot be mounted; 10 slots.
Appli cable CPU Unit: CS1 CPU Unit 3G8F7-SLK21-E.
Basic I/O Units: CS-series Basic I/O Unit,
Yes; C200H series Basic I/O Unit, No;
C200H Group-2 High density I/O Unit, No.
Special I/O Units: CS-series Special I/O Unit,
Yes; C200H series Special I/O Unit, No.
CPU Bus Units: CS-series CPU Bus Unit, Yes.
Current consumption: 5V system, 0.11A;
26 V system, --.
Standards: U, C, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control 3G8F7-SLK21-E. Unit type: CS1 Special analog I/O Units.
Product name: Analog Output Units.
Specifications: I/O points, 8 outputs;
Signal range selection,
Set separately for each input;
Signal range, 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 V to 10 V, 4 to 20 mA;
Resolution, 1/4000 ;
Conversion speed, 1 s/point.
Externa connection, Removable erminal block.
Current consumption: 5V, 0.13A; 26V, 0.18A.
Standards: UC1, N, CE.
For Various Analog I/Os.
Analog Input Units for converting,
analog input signals into binary data.
Analog Output Units for converting ,
binary data into analog output signals.Unit type: CS1 Special I/O Units.
Product name: Isolated-type Resistance,
Thermometer Input Units (Ni508.4 Ω).
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: INi508.4.
Conversion speed (resolution):
100 ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.15A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost annd space compared,
with previous systems 3G8F7-SLK21-E.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems 3G8F7-SLK21-E.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.


...More relevant models >>>>