(without Voltage Reduction Unit) A22L-H.
Output: SPST-NC + SPST-NC.
Lighting: LED.
Operating voltage: 24 VAC/VDC.
Operation: Alternate operation (self-holding).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit.
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models).
High-capacity Switch Capable of,
Handling 20 A Loads with Large.
Inrush Currents.
Same shape as OMRON Z Basic Switches except in pin,
plunger position, yet endures inrush currents as large as 75 A. Output: DPDT.
Lighting: LED without Voltage Reduction Unit.
Operating voltage: 24 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white A22L-HY-24A-02A
A22L-HY-24A-02A
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1 A22L-HY-24A-02A. Conduit: JIS B 0202 G½.
Applicable cable: Cabtire cable (anticorrosive).
Inner diameter (D)of seal rubber: 14 mm.
External diameter of cable: Min, 12 mm; Max, 14 mm.
Applicable model: WL-N, WL, D4A-@N, D4B-@N, ZE, ZV, ZV2, XE, XV, XV2.
Connectors (SC Series).
Cabtire cables and flexible tubes with various diameters are used to,
connect machine tools and controllers with Limit Switches A22L-HY-24A-02A. To ensure,
the watertightness of the edges of the conduits, use an SC Connector,
that is suitable for the external diameter of cable and model of Limit Switch. Ratings: Standard load; 5 A at 125 VAC.
Cable: VCTF oil-resistant cable *1.
Actuator: Sealed crossroller plunger.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
CCable lengths of 3 and 5 m available on standard models A22L-HY-24A-02A.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
connfirmation of operation A22L-HY-24A-02A.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)