Unit type: CJ1 Basic I/O Units.
Product name: DC Input Units.
Removable terminal block; No. of words allocated, 1 word.
Current consumption: 5V, 0.09A; 24V, --.
Standards: UC1, N, L, CE.
Different Applications.
I/O memory in the CPU Unit.
CJ1W-ID233 are now available. These units can,
help to increase system throughput.
Unit type: CJ1 CPU Bus Units.
Product Name: Position Control,
Units with EtherCAT interface.
Specifications: Control output interface,
Control commands executed by,
EtherCAT communications.
Positioning functions: Memory operation,
Direct operation by ladder programming,
I/O communications: 64 nodes;
No CJ1W-ID201. of axes: 16 axes.
No. of unit numbers allocated: 1.
Current consumption : 5V, 0
CJ1W-ID20146A; 24V,--.
Standards: UC1, CE.
Preeminent control performance and,
easy operation feature of EtherCAT,
improve the production efficiency.
The EtherCAT communications with,
100Mbps baud rate enables fast,
and accurate position control.
A wide range of position control,
functions are available with,
this position control unit CJ1W-ID201. Unit classification: CJ1 Special I/O Units.
Product name: ProcessInput Units,
(Isolated-type Thermocouple Input Units).
Input points: 4 inputs.
Signal range selection: Common inputs.
Signal range: Thermocouple: R, S, K, J, T, L, B.
Conversion speed (resolution): Conversion,
speed: 250 ms/4 inputs.
Accuracy at ambient temperature of 25°C:
Accuracy: (±0 CJ1W-ID201. 3% of PV or ±1°C,
whichever is larger) ±1 digit max.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four input channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage).
All inputs are isolated. Unit type: CJ1 Special I/O Units.
Product name: Analog Output Unit.
I/O points: 4 inputs ; 2 outputs.
Signal range selection:
Set separately for each input and output.
Signal range, Resolution: 1 to 5 V,
0 to 5 V, 0 to 10 V, -10 to 10 V,
4 to 20 mA.
Resolution: 1/4,000 (Settable to 1/8,000).
Conversion period: 1 ms/point,
(Settable to 500 μs/point).
Accuracy at ambient temperature of 25°C:
Voltage: ±0.2% of F.S. Current: ±0.2% of F.S;
Voltage: ±0.3% of F.S. Current: ±0.3% of F.S.
External connection: Removable terminal block.
External powerr supply: 24 VDC +10% -15%, 140mA max CJ1W-ID201.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.58A; 24V, --.
Standards: UC1, N, L, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Anaalog Input Units for converting analog input,
signals into binary data CJ1W-ID201.
Analog Output Units for converting binary ,
data into analog output signals.