CJ1W-MAD42 Analog I/O Unit

OMRON CJ1W-MAD42 Manual And Instructions
CJ1W-MAD42 datasheetPDF datasheet
CJ1W-MAD42 PROGRAMMING MANUAL
CJ1W-MAD42 OPERATION MANUAL
CJ1W-MAD42 Instruction Installation Sheet

OMRON CJ1W-MAD42 Product information and technical parameters:
Brand: OMRON
Name: Analog I/O Unit
Model: CJ1W-MAD42
Unit type: CJ1 Special I/O Units.
Product name: Analog Output Unit.
I/O points: 4 inputs ; 2 outputs.
Signal range selection:
Set separately for each input and output.
Signal range, Resolution: 1 to 5 V,
0 to 5 V, 0 to 10 V, -10 to 10 V,
4 to 20 mA.
Resolution: 1/4,000 (Settable to 1/8,000).
Conversion period: 1 ms/point,
(Settable to 500 μs/point).
Accuracy at ambient temperature of 25°C:
Voltage: ±0.2% of F.S. Current: ±0.2% of F.S;
Voltage: ±0.3% of F.S. Current: ±0.3% of F.S.
External connection: Removable terminal block.
External power supply: 24 VDC +10% -15%, 140mA max.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.58A; 24V, --.
Standards: UC1, N, L, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Analog Input Units for converting analog input,
signals into binary data.
Analog Output Units for converting binary ,
data into analog output signals.

Type: CS Special I/O Unit.
Connected ID System: V680 Series; 1 Head.
External power supply: --.
No. of unit numbers used: 1 unit number.
Current consumption: 5V, 0.26A;
24V, 0.13A; External, --.
Communication Unit Dedicated for RFID V680,
Allowing Direct Connection to OMRON PLC CJ/
CS/NJ-series CJ1W-MAD42.
Communication unit for connecting RFID V680-series,
which can be used around the world, directly to PLC CJ1W-MAD42
Allows batch transfer of data up to 32 kbytes.Unit type: CJ1 Basic I/O Units.
Product name: Transistor Output Units.
Specifications: Output type, Sinking;
I/O points, 64 outputs;
Maximum switching capacity, 24VDC, 0.3A;
Commons, 16 points, 1 common;
External connection, Fujitsu connector CJ1W-MAD42.
No. of words allocated: 4 words.
Current consumption: 5V, 0.17A; 24V, --.
Standards: UC1, N, L, CE.
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications.
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system CJ1W-MAD42.
throughput. Unit classification: CJ1 Special I/O Units.
Product name: Temperature Control Units.
Specifications; No. of loops: 4 loops;
Temperature sensor inputs: Thermocouple,
input (R, S, K, J, T, B, L);
Control outputs: Open collector NPN outputs (pulses).
No. of unit numbers allocated: 2.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, N, L, CE.
A Single Unit Performing All the Functions of,
4 Temperature Controllers.
A Special I/O Unit with direct input,
of thermocouple or resistance thermometer,
PID control with 2 degrees of freedom,
and open collector output. Unit type: CJ1 Special I/O Units.
Product name: Analog Output Unit.
I/O points: 4 outputs;
Signal range selection:
Set separately for each output.
Signal range, Resolution: 1 to 5 V,
0 to 5 V, 0 to 10 V, -10 to 10 V,
4 to 20 mA; 1/4,00.
Conversion period: 1 ms/point.
Accuracy at ambient temperature of 25°C:
Voltage: ±0.3% of F.S. Current: ±0.5% of F.S.
External connection: Removable terminal block.
External power suppply: 24 VDC +10% -15%, 200mA max CJ1W-MAD42.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 24V, 0.2*3.
Standards: UC1, N, L, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Anallog Input Units for converting analog input,
signals into binary data CJ1W-MAD42.
Analog Output Units for converting binary ,
data into analog output signals.