Unit classification: CJ1 Special I/O Units.
(High Speed type).
Number of control axes : 4 axes.
No. of unit numbers allocated: 2.
Current consumption: 5V, 0.31A; 24V, --.
Standards: UC1, CE.
Synchronization and Even Higher Speed.
and open-collector or line-driver outputs.
and the CJ1W-NC234/NC434 have line-driver outputs.
and direct drive motors.
Unit type: CJ1 Basic I/O Units.
name: B7A Interface Units.
Specifications: I/O points, 64 inputs;
External connection, Removable terminal block.
No. of words allocated: 4 words.
Current consumption: 5V, 0.07A; 24V, --.
Standards: UC1, CE.
It transmits 16 points of I/O signals per,
word with a pair of cables CJ1W-NC414.
Easy and minimized wiring effort,
The B7A Interface Unit and B7A Link Terminal,
can be used in the same way as a standard,
Basic I/O Unit and I/O Terminal without,
any need to worry about communications
CJ1W-NC414
This characteristic reduces the wiring,
when using more than one relatively remote,
sensor or actuator. Unit type: CJ1 Basic I/O Units.
Product name: Transistor Output Units CJ1W-NC414.
Specifications: Output type, Sinking;
I/O points, 32 outputs;
Maximum switching capacity, 12 to 24VDC, 0.5A;
Commons, 16 points, 1 common;
External connection, Fujitsu connector.
No. of words allocated: 2 words.
Current consumption: 5V, 0.14A; 24V, --.
Standards: UC1, N, L, CE.
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications CJ1W-NC414.
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system.
throughput. Unit type: CJ1 Basic I/O Units.
Product name: Quick-response Input Unit.
Specifications: I/O points, 16 inputs;
Input voltage current, 24VDC, 7mA;
Commons: 16 points, 1 common;
Input pulse widt conditions, ON time:
0.05 ms max. OFF time: 0.5 ms max;
Max. Units mountable per Unit, 2;
External connection, Removable terminal block.
No. of words allocated: 1 word.
Current consumption: 5V, 0.08A; 24V, --.
Standards: UC1, N, L, CE.
Capture Input Signals Shorter,
Than the Cycle Time.
This Input Unit can read pulse inputs that,
are shorter than the cycle time of the CPU Unit. Unit classification: CJ1 Special I/O Units.
Product name: Process Analog Input Units,
(Isolated-type Resistance Thermometer Input Units).
Input points: 4 inputs.
Signal range selection: Common inputs.
Signal range: Resistance thermometer: Pt100, JPt100.
Conversion speed (resolution): Conversion,
speed: 250 ms/4 inputs.
Accuracy at ambient temperature of 25°C:
Accuracy: (±0.3% of PV or ±0.8°C,
whichever is larger) ±1 digit max.
External connection: Removable terminal block.
No. of unit numbers allocatedd: 1 CJ1W-NC414.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four inputt channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage) CJ1W-NC414.
All inputs are isolated.