Home >> Products >> OMRON >> CJ2/CJ1 PLC >> CPU high function unit >> Position control unit with EtherCAT/MECHATROLINK-II interface >> CJ1W-NC882 Position Control Units with EtherCAT interface

CJ1W-NC882 Position Control Units with EtherCAT interface

OMRON CJ1W-NC882 Manual And Instructions
CJ1W-NC882 datasheetPDF datasheet
CJ1W-NC882 PROGRAMMING MANUAL
CJ1W-NC882 safety precautions

OMRON CJ1W-NC882 Product information and technical parameters:
Brand: OMRON
Name: Position Control Units with EtherCAT interface
Model: CJ1W-NC882
Unit type: CJ1 CPU Bus Units.
Product Name: Position Control,
Units with EtherCAT interface.
Specifications: Control output interface,
Control commands executed by,
EtherCAT communications.
Positioning functions: Memory operation,
Direct operation by ladder programming,
I/O communications: 64 nodes;
No. of axes: 8 axes.
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.46A; 24V,--.
Standards: UC1, CE.
Preeminent control performance and,
easy operation feature of EtherCAT,
improve the production efficiency.
The EtherCAT communications with,
100Mbps baud rate enables fast,
and accurate position control.
A wide range of position control,
functions are available with,
this position control unit.

Unit classification: CJ1 CPU Bus Unit.
Product name: EtherNet/IP Unit.
Specifications:Communications cable,
Shielded twisted-pair STP),
cable Categories: 100 Ω at 5,5e;
Communications functions, Tag Data Link,
Functions, Message Communications Functions;
Units per CPU Unit, 8 max.
No. of unit numbers allocated: 1 CJ1W-NC882.
Current consumption: 5V system, 0.41A;
24V system, --.
Standards: UC1, N, L, CE CJ1W-NC882
Introducing the New EtherNet/IP Unit.
More Than 180,000 Words of Tag,
Data Link Capacity!
EtherNet/IP is an industrial multivendor,
network that uses Ethernet.
Managed by the ODVA (Open DeviceNet Vendors,
Association), it has open standards and is,
used with a wide range of industrial devices CJ1W-NC882.
The EtherNet/IP Unit supports tag data links,
to enable sharing data between devices at,
Ethernet nodes and a message service for,
sending and receiving data when required.
The EtherNet/IP Unit supports the same,
FINS/UDP and FINS/TCP functionality,
as Ethernet Units.
Product name: CJ1M CPU Units; built-in I/O.
Specifications: I/O capacity/Mountable Units Expansion Racks),
320 points/10 Units (No Expansion Rack); Program capacity,
10K steps; Data memory capacity, 32K words(DM: 32K words, EM: None);
LD nstruction execution time, 0 CJ1W-NC882. 1 μs;
Built-in I/O , 10 inputs and6 outputs,
2 counter inputs, 2 pulse outputs.
Current consumption: 5v, 0.64A (Seenote 1.) ; 24V,--.
Standards: UC1, N, L, CE.
Versatile Machine Control with the,
Highest Performance Standards in the Industry. Product name: Transistor Output Units.
Specifications: Output type, Sourcing;
I/O points, 16 outputs;
Maximum switching capacity, 24VDC,
0.5A Short-circuit protection;
Commons, 16 points, 1 common;
External connection, Removable terminal block.
No. of words allocated: 1 word.
Currennt consumption: 5V, 0 CJ1W-NC882. 10A; 24V, --.
Standards: UC1, N, L, CE.
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications.
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices CJ1W-NC882.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system.
throughput.