OMRON
Home >> Products >> OMRON >> Master slave station products >> CompoNet >> CRT1B-ID02S Bit Slave Units with e-CON Connectors

CRT1B-ID02S Bit Slave Units with e-CON Connectors

OMRON CRT1B-ID02S Manual And Instructions
CRT1B-ID02S datasheetPDF datasheet

OMRON CRT1B-ID02S Product information and technical parameters:
Brand: OMRON
Name: Bit Slave Units with e-CON Connectors
Model: CRT1B-ID02S
Name: Bit Slave Units with e-CON Connectors.
Specifications: Inputs; 2 inputs; NPN.
Simple and Intelligent Bit Slaves,
with Industry-standard e-CON connectors.
Slave Units capable of 2-point bit-level distribution.
The I/O power supply is supplied from the communications,
power in the previously connected flat cable, and has a,
short-circuit detection function for protection.
Industry-standard e-CON connectors.
Short-circuit protection safeguards the network,
from I/O short circuits.
Simple communications connections,
with flat cable and connectors.
Bit-level distribution to support,
essentially any application.

Specifications: Outputs; NPN (- common);
16 points.
I/O connections: M3 screw terminals.
Rated internal circuit power supply voltage:
Supplied from Basic Unit.
I/O power supply voltage: 24 VDC.
A Smart Slave with a 3-tier Terminal,
Block That Means Wiring Locations,
Are Easy to Understand with No,
Sharing of Terminals CRT1B-ID02S.
Easy wiring with no sharing of terminals.
Easy-to-understand wiring locations CRT1B-ID02S
No relay terminal block terminals required.
Detachable cassette-type circuit sections. Short/disconnection detection: Supported.
Specifications: Inputs, PNP (- common), 32 points.
I/O connections: Clamp terminals.
Rated internal circuit power supply voltage:
Supplied from communications connector CRT1B-ID02S.
Rated I/O power supply voltage: 24 VDC.
Reduced Wiring and Labor on Factory Sites with Screw-less Terminal Wiring.
Screw-less structure eliminates tightening work.
Detachable terminal blocks for easier maintenance.
Single-step wiring by simply inserting pole terminals. Name: Clamp Terminal Blocks.
Specifications: Inputs; 8 inputs ; PNP; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet CRT1B-ID02S.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Specifications: I/O; PNP (input: - common,
output: + common)); Input:
8 points/Output: 8 points.
I/O connections: M3 screw terminals.
Rated internal circuiit power supply voltage:
Supplied from Basic Unit CRT1B-ID02S.
I/O power supply voltage: 24 VDC.
A Smart Slave with a 3-tier Terminal,
Block That Means Wiring Locations,
Are Easy to Understand with No,
Sharing of Terminals.
Easy wiring with nno sharing of terminals CRT1B-ID02S.
Easy-to-understand wiring locations.
No relay terminal block terminals required.
Detachable cassette-type circuit sections.


...More relevant models >>>>