Name: CS1D CPU Unit for Single CPU Systems.
Interrupt functions, OK.
26V system, --.
Standards: UC1, N, L, CE.
and Expansion I/O Cables.
Name: CS1D CPU Unit for Single CPU Systems.
Specifications: Number of I/O points,
1280 points (3 Racks);
Program capacity, 30 Ksteps;
Data Memory, 64 Kwords(DM: 32 Kwords,
EM: 32 Kwords×1 bank);
LD execution time, 0.04 μs;
Duplex CPUs, --;
Interrupt functions, OK.
Current consumption: 5V system, 0 CS1D-CPU65S. 78A;
26V system, --.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables
CS1D-CPU65S Unit type: CS1 Basic I/O Units.
Product name: Relay Output Units.
Specifications: 12 to 24 VDC,
0.5A . 16 outputs; Sinking.
Mountable Racks: CPU Rack, CS1W-BC,
@@3, Yes, @@2, Yes;
C200HX/HG/HE Expansion I/O Rack, No.
CS1 Expansion Rack, CS1W-BI,
@@3, Yes, @@2, Yes;
CS1 Long distance Expansion Rack, Yes;
SYSMAC BUS Slave Rack, No CS1D-CPU65S.
Words required: 1 word.
Current consumption: 5V system, 0.17A;
26 V system, --.
Standards: UC1, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Thermocouple Input Units CS1D-CPU65S.
points Input: 8 inputs.
Signal range selection:
Set separately for each input.
I/O type: R, S, K, J, T, L, B.
Conversion speed: 250 ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.18A; 26V, 0.06A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems CS1D-CPU65S.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CS1D-CPU65S.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.