Unit type: CS1 Basic I/O Units.
Product name: DC Input/Transistor Output Unit.
Specifications: 24 VDC, 6 mA 32 inputs.
Mountable Racks: CPU Rack, CS1W-BC,
@@3, Yes, @@2, Yes;
C200HX/HG/HE Expansion I/O Rack, No.
CS1 Expansion Rack, CS1W-BI,
@@3, Yes, @@2, Yes;
CS1 Long distance Expansion Rack, Yes;
SYSMAC BUS Slave Rack, No CS1H-CPU66H.
Words required: 2 input words and 2 output words.
Current consumption: 5V system, 0
CS1H-CPU66H27A;
26 V system, --.
Standards: U, C, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. Specifications: Optical ring (HPCF cable).Type: Counter inputs, pulse outputs.
12 DC inputs: Yes.
Counter inputs: 2.
Analog inputs: None CS1H-CPU66H.
8 transistor outputs: Yes.
2 pulse outputs: No.
2 analog outputs: Yes.Name: CS1D CPU Unit for Duplex CPU Systems.
Specifications: Number of I/O points,
5,120 points (7 Racks);
Program capacity, 60 Ksteps;
Data Memory, 128 Kwords,
(DM: 32 Kwords, EM: 32 Kwords×3banks);
LD execution time, 0.02 μs;
Duplex CPUs, OK;
Interrupt functions, --.
Current consumption: 5 V system, 0.82A;
26 V system, -- CS1H-CPU66H.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables. Unit type: CS1 Basic I/O Units.
Product name: Relay Output Units.
Specifications:124 VDC, 0.5 A,
16 outputs; Sourcing.
Mountable Racks: CPU Rack, CS1W-BC,
@@3, Yes, @@2, Yes;
C200HX/HG/HE Expansion I/O Rack, No.
CS1 Expansion Rack, CS1W-BI,
@@3, Yes, @@2, Yes;
CS1 Long distance Expansion Rack, Yes;
SYSMAC BUS Slave Rack, No.
Words required: 1 word.
Current consumption: 5V system, 0.17A;
26 V system, --.
Standards: UC1, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. Unit type: CS1 CPU Bus Units.
Product Name: MECHATROLINK-II,
compatible Position Control Unit.
Specifications: Control commands,
executed by MECHATROLINK-II,
synchronous communications.
Direct operation by ladder,
programming, Control mode:
Position control, speed control,
or torque control; No. of axes: 2.
No. of uniit numbers allocated: 1 CS1H-CPU66H.
Current consumption: 5V, 0.36A; 26V, --.
Standards: UC1, CE.
Decrease TCO with Simple Operation,
Reduced Wiring, Batch Settings,
and Batch Management.
Control Servos for up to 16 axes,
in a motion networkk with one Position,
Control Unit that supports MECHATROLINK-II CS1H-CPU66H.
MECHATROLINK-II is a registered trademark,
of the MECHATROLINK Members Association.