Name: I/O Control Unit.
Long-distance Connecting Cable.
26V system, --.
Standards: U, C, N, L, CE.
and Expansion I/O Cables.
I/O bits: 5, 120 (Expan-sion Racks: 7).
Program capacity: 60K steps.
Data memory capacity: 128K words (DM: 32K words, EM: 32K words ×3 banks).Unit type: CS1 Special I/O Units.
name: Position control unit.
Specifications: Control method/Control,
output interface, Open-loop control by,
pulse train output/Open-collector output;
Number of control axes, 4 axis CS1W-IC102.
No. of unit numbers allocated: 2
CS1W-IC102
Current consumption: 5V, 0.36A; 26V, --.
Standards: U, C, N, L, CE.
High-speed, High-precision,
positioning with 1, 2, or 4 axes.
Versatile functions and superb,
performance enable the construction,
of compact, high-performance machines.
With its ultra-compact size of 31×90mm,
(W×H),this highly space-efficient Position,
Control Unit(PCU) enables up to 4 axes,
of motor control CS1W-IC102. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Analog Output Unit.
Output points : 4 inputs.
Signal range selection:
Set separately for each input.
Signal range: 4 to 20 mA, 1 to 5 V.
Conversion speed (resolution):
100ms/4 inputs.
Externa connection: Removable erminal block CS1W-IC102.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.16A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in costt and space compared,
with previous systems CS1W-IC102.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CS1W-IC102.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.