OMRON
Home >> Products >> OMRON >> CS1G/CS1H/CS1D/CS1W PLC >> CS1 series PLC high performance I/O unit >> CS1 series process simulation I/O unit >> CS1W-PMV01 Process Analog I/O Units

CS1W-PMV01 Process Analog I/O Units

OMRON CS1W-PMV01 Manual And Instructions
CS1W-PMV01 datasheetPDF datasheet
CS1W-PMV01 Operation Manual

OMRON CS1W-PMV01 Product information and technical parameters:
Brand: OMRON
Name: Process Analog I/O Units
Model: CS1W-PMV01
Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Analog Output Unit.
Output points : 4 inputs.
Signal range selection:
Set separately for each input.
Signal range: 4 to 20 mA, 1 to 5 V.
Conversion speed (resolution):
100ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.16A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.

Product name: CS1 CPU Backplane.
Specifications: For CS-series,
Unit only Note: C200H series,
Units cannot be mounted; 10 slots.
Appli cable CPU Unit: CS1 CPU Unit.
Basic I/O Units: CS-series Basic I/O Unit,
Yes; C200H series Basic I/O Unit, No;
C200H Group-2 High density I/O Unit, No.
Special I/O Units: CS-series Special I/O Unit,
Yes; C200H series Special I/O Unit, No CS1W-PMV01.
CPU Bus Units: CS-series CPU Bus Unit, Yes CS1W-PMV01
Current consumption: 5V system, 0.11A;
26 V system, --.
Standards: U, C, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. Unit type: CS1 CPU Bus Unit.
Product name:Ethernet Units.
Specifications: Communi cations cable,
100BASE TX Cable; Communications functions,
FINS communications service(TCP/IP and UDP/IP),
FTP server function, socket service,
mail send service, mail reception,
(remote command reception),
auto-adjustment of PLC''s internal clock,
and server host name specification;
Duplexing, Not supported;
Units per CPU Unit, 4 Units CS1W-PMV01.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0 CS1W-PMV01. 38A; 26V, --.
Standards: UC1, N, L, CE.
Organically Connect the Production,
Site and Management.
Select the required communications,
services according to application needs,
to flexibly integrate PLCs with an,
Ethernet information network.Name: AC Power Supply Unit.
Power supply voltage:
100 to 120 V AC or 200 to 240 V AC.
Output capacity: 5 VDC output capacity, 7A;
26 VDC output capacity, 1.3A;
Total, 35W.
Options: 24 V DC service power supply, No;
RUN output, Yes.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables. Unit type: CS1 Special I/O Units.
Product name: Analog Input Unit (100 mV).
Input points : 8 inputs.
Signal range: 0 to 100 mV, ±100 mV.
Conversion speed (resolution):
200ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.08A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in costt and space compared,
with previous systems CS1W-PMV01.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CS1W-PMV01.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.


...More relevant models >>>>