Receptacle box: G 1/2 Conduit.
Indicator: Without indicator.
Actuator: Side plunger, Adjustable.
Approved standards: UL, CSA.
Shock Resistance, and Strength.
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13).
-40°C to +100°C (standard type).
Models with fluoro-rubber available for greater resistance to chemicals.
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models available for complex operations.
Approved by UL, CSA, and CCC (Chinese standard).
Receptacle box: G 1/2 Conduit.
Indicator: With neon lamp indicator (AC).
Actuator: Roller lever *1, Maintained *2.
Approved standards: UL, CSA.
The Limit Switch with Better Seal,
Shock Resistance, and Strength.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13) D4A-4508N.
Wide standard operating temperature range:
-40°C to +100°C (standard type)
D4A-4508N
Models with fluoro-rubber available for greater resistance to chemicals.
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models available for complex operations.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved model D4A-4508N. ) Ratings: 0.1 A at 30 VDC.
Cable: VCTF oil-resistant cable*.
Actuator: Pin plunger.
Cable length : 5m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material D4A-4508N.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.) Drive rod: leaf Shibai rod type.
Contactt specifications: 1b D4A-4508N.
Rating: small load with 0.1A.
For the automobile, industrial vehicles, mechanical testing of the anti immersion type (in line with IP67)
Use M4 screw to achieve a little installation.
Using a strong fixed leaf swiing rod which can adapt to the harsh environment D4A-4508N.
Full consideration of environmental protection, the installation of the wire also lead to lead free.