OMRON
Home >> Products >> OMRON >> Security products >> Safety door switch >> D4BL-2CRG Guard Lock Safety-door Switch

D4BL-2CRG Guard Lock Safety-door Switch

OMRON D4BL-2CRG Manual And Instructions
D4BL-2CRG datasheetPDF datasheet
D4BL-2CRG INSTRUCTION sheet

OMRON D4BL-2CRG Product information and technical parameters:
Brand: OMRON
Name: Guard Lock Safety-door Switch
Model: D4BL-2CRG
Lock method: Solenoid lock.
Conduit size: G1/2.
Voltage for solenoid: 24 VDC.
Without indicator 1NC/1NO+ 1NC (Slow-action).
Release Protective Cover Locks Using.
Controller Signals or Pushbutton.
Switches after the Cutting Tool Stops.
Moving Due to Inertia.
A mechanical lock is applied automatically when the Operation.
Key is inserted. A high level of safety is achieved using a,
mechanism where the lock is only released when voltage is,
applied to the solenoid.
Conforms to EN (TÜV) standards corresponding to the CE marking.
Certified by UL, CSA and CCC standards.
The Switch contact is opened by a direct opening mechanism,
(NC contacts only) when the protective cover is opened.
Direct opening mechanism that is EN-certified is indicated by,
on the Switch.
Auxiliary release key ensures easy maintenance and unlocks the,
door in the case of a power failure.
Tough aluminum die-cast body incorporating a switch box with,
degree of protection satisfying IP67, UL, and CSA TYPE6P, 13.
Equipped with a horizontal and vertical conduit opening.
Models incorporating easy-to-see indicators for monitoring and,
those using an adjustable Operation Key for a swinging door are available.
The mounting direction of the head can be changed,
to allow the Operation Key to be inserted from four directions.

Lock method: Mechanical lock.
Conduit size: M20.
Voltage for solenoid: 24 VDC.
Without indicator 2NC+ 1NC (Slow-action).
Release Protective Cover Locks Using.
Controller Signals or Pushbutton.
Switches after the Cutting Tool Stops.
Moving Due to Inertia.
A mechanical lock is applied automatically when the Operation D4BL-2CRG.
Key is inserted. A high level of safety is achieved using a,
mechanism where the lock is only released when voltage is,
applied to the solenoid D4BL-2CRG
Conforms to EN (TÜV) standards corresponding to the CE marking.
Certified by UL, CSA and CCC standards.
The Switch contact is opened by a direct opening mechanism,
(NC contacts only) when the protective cover is opened.
Direct opening mechanism that is EN-certified is indicated by,
on the Switch D4BL-2CRG.
Auxiliary release key ensures easy maintenance and unlocks the,
door in the case of a power failure.
Tough aluminum die-cast body incorporating a switch box with,
degree of protection satisfying IP67, UL, and CSA TYPE6P, 13.
Equipped with a horizontal and vertical conduit opening.
Models incorporating easy-to-see indicators for monitoring and,
those using an adjustable Operation Key for a swinging door are available D4BL-2CRG.
The mounting direction of the head can be changed,
to allow the Operation Key to be inserted from four directions. Actuator: Arm lever.
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 2NC/1NO MBB (Slow-action).
Compact, Plastic-body Safety-door.
Hinge Switch Designed for Saving.
Space in Machines and Other.
Equipment.
Lineup includes three contact models with 2NC/1NO and.
3NC contact forms in addition to the previous contact forms.
1NC/1NO, and 2NC. Models with MBB contacts are also available.
Standardized gold-clad contacts providde high contact reliability D4BL-2CRG.
Can be used with both standard loads and microloads. Number of beams: 65.
Protective height: 1620mm.
Model: PNP output.
Basic Type with a combination of.
performance and functionality.
Up to three sets off series-connected sensors D4BL-2CRG.
The muting function is enabled simply with Muting Key Cap.
Comes standard with interlock and auxiliary output functions.


...More relevant models >>>>