Actuator: Adjustable roller lever, form lock (metal lever, rubber roller).
Conduit size: 1-conduit; M12 connector.
Built-in switch mechanism: 1NC/1NO (Slow-action).
A Series of Pull-reset Models Now.
Available.
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC.
Operating: Appearance, 40-dia. head Medium Push-lock Turn-reset With EMS, Indication; Contact Configuration, 1NO + 2NC (1NC + 1NC) .
Color of cap: Red.
Install in 22-dia. or 25-dia. Panel Cutout.
Direct opening mechanism to open the circuit when the contact welds.
Safety lock mechanism prevents operating errors D4N-9A2HR.
Easy mounting and removal of Switch Blocks using a lever.
Mount three Switch Units in series to improve wiring efficiency,
(with non-lighted Switch Units, three Units can be mounted for,
multiple contacts)
D4N-9A2HR
Finger protection mechanism on Switch Unit provided as a,
standard feature.
Install using either round, or forked crimp terminals.
Oil-resistant to IP65 (non-lighted models)/IP65 (lighted models),
A lock plate is provided as a standard feature to ensure that the,
control box and switch are not easily separated D4N-9A2HR. Number of beams: 56.
Protective height: 1395mm.
Model: PNP output.
Basic Type with a combination of.
performance and functionality.
Up to three sets of series-connected sensors.
The muting function is enabled simply with Muting Key Cap.
Comes standard with interlock and auxiliary output functions D4N-9A2HR. The Special Operation Key Activates a Direct.
Opening Mechanism to Open the Contacts.
and Shut Off Control Circuits when Protective.
Doors Are Opened on Machine Tools or Other.
Equipment.
Conforms to EN (TÜV) standards corresponding to the CE marking.
Certified by UL and CSA standards.
The Switch contact is opened by a direct opening mechanism,
(NC contacts only) when the protective cover is opened. The EN-certified.
direct opening mechanism is indicated by on the Switch.
Malfunctions and false operation prevented by special Operation Key.
Wide temperature range specifications: −40 to 80°C.
Degree of protection of the switch box: IP67 (EN60947-5-1). Actuator: Adjustable roller lever, form lock (metal lever, rubber roller).
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 2NC/1NO (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC conntact forms D4N-9A2HR.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used witth both standard loads and microloads D4N-9A2HR.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC.