Actuator: One-way roller arm lever (vertical).
Conduit size: 1-conduit; M12 connector.
Built-in switch mechanism: 2NC (Slow-action).
Popular Safety Limit Switches.
International Standards.
3NC contact forms.
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC.
Number of beams: 22.
Protective height: 465mm.
Model: NPN output.
Basic Type with a combination of.
performance and functionality.
Up to three sets of series-connected sensors.
The muting function is enabled simply with Muting Key Cap.
Comes standard with interlock and auxiliary output functions D4N-9B72. Actuator: Adjustable roller lever, form lock (metal lever, rubber roller).
Conduit size: 1-conduit; Pg13
D4N-9B725.
Built-in switch mechanism: 2NC/1NO (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
M12-connector models are available, saving on labor and,
simplifying replacement D4N-9B72.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Number of beams: 56.
Protective height: 1150mm.
Previously light curtains only offered status indicators.
The three types of indicators on the F3SR-B are not only,
status indicators but enable D4N-9B72.
the user to completely understand the status at a glance,
further enhancing usability. Number of beams: 88.
Protective height: 1760mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions. Name: Safety Network Controllers.
No. of I/O points: Safety inputs, 16; Test outputs, 4; Safety outputs, 8.
Unit version: 2.0.
Achieve Safety Control through,
Programming.
Compact Safeety Controller D4N-9B72.
The NE1A-SCPU01-V1 provides 16 built-in safety inputs,
and 8 built-in safety outputs.
The NE1A-SCPU02 provides 40 built-in safety inputs and,
8 built-in safety outputs.
Reduced wiring with safety networks. Connect up too 32,
Safety Terminals D4N-9B72.
Monitor the safety system from Standard Controllers,
across the network.
ISO13849-1 (PLe) and IEC 61508 SIL3 certification.