Actuator: One-way roller arm lever (vertical).
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 3NC (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC D4SL-N4CFA-N.
M12-connector models are available, saving on labor and,
simplifying replacement
D4SL-N4CFA-N
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Number of beams: 54.
Protective height: 1105mm.
Model: NPN output.
EASY type reduces implementation costs D4SL-N4CFA-N.
with 1/2 the mounting time.
In pursuit of simple functions: Upon detection of personnel,
the machine stops.
Can be used for simple hand intrusion detection.
Implementation costs can be significantly reduced. Number of beams: 74.
Protective height: 1480mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions D4SL-N4CFA-N.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions. Actuator: Roller lever (resin lever, resin roller).
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 1NC/1NO (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contacct forms D4SL-N4CFA-N.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used witth both standard loads and microloads D4SL-N4CFA-N.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC.