Lock method: Mechanical lock.
Conduit size: G1/2.
Voltage for solenoid: 24 VDC.
Without indicator 2NC+ 1NC (Slow-action).
Release Protective Cover Locks Using.
Controller Signals or Pushbutton.
Switches after the Cutting Tool Stops.
Moving Due to Inertia.
A mechanical lock is applied automatically when the Operation D4SL-N4RFA-D4.
Key is inserted. A high level of safety is achieved using a,
mechanism where the lock is only released when voltage is,
applied to the solenoid
D4SL-N4RFA-D4
Conforms to EN (TÜV) standards corresponding to the CE marking.
Certified by UL, CSA and CCC standards.
The Switch contact is opened by a direct opening mechanism,
(NC contacts only) when the protective cover is opened.
Direct opening mechanism that is EN-certified is indicated by,
on the Switch D4SL-N4RFA-D4.
Auxiliary release key ensures easy maintenance and unlocks the,
door in the case of a power failure.
Tough aluminum die-cast body incorporating a switch box with,
degree of protection satisfying IP67, UL, and CSA TYPE6P, 13.
Equipped with a horizontal and vertical conduit opening.
Models incorporating easy-to-see indicators for monitoring and,
those using an adjustable Operation Key for a swinging door are available D4SL-N4RFA-D4.
The mounting direction of the head can be changed,
to allow the Operation Key to be inserted from four directions. Number of beams: 13.
Protective height: 620mm.
Model: PNP output.
Basic Type with a combination of.
performance and functionality.
Up to three sets of series-connected sensors.
The muting function is enabled simply with Muting Key Cap.
Comes standard with interlock and auxiliary output functions. Number of beams: 100.
Protective height: 1505mm.
Model: NPN output.
Basic Type with a combination of.
performance and functionality.
Up to three sets of series-connected sensors.
The mutting function is enabled simply with Muting Key Cap D4SL-N4RFA-D4.
Comes standard with interlock and auxiliary output functions. Number of beams: 28.
Protective height: 590mm.
Model: NPN.
Easy-to-use Safety Sensor Ideal for.
Simple On/Off Detecction Applications D4SL-N4RFA-D4.
Provides simple safety functions - saving TCO.
by reducing errors.
Simple wiring with only 4 wires.
Fast response time of 5 ms.