16 inputs/16 outputs.
I/O connections: MIL connector.
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Very Compact 16-/32-point Remote Terminals.
connect to a wide range of interfaces.
35 x 60 x 80 mm (W x D x H).
Name: System Units; I/O Power Feed Unit.
Specifications: Use when the total current,
consumption of the I/O Power Supply exceeds 4 A,
or to make the I/O Power Supply a separate system.
Standards: CE, UC, L.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet DRT2-MD32ML.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system
DRT2-MD32ML
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error DRT2-MD32ML. Name: Bit Slave Units with e-CON Connectors.
Specifications: Inputs; 2 inputs; NPN.
Simple and Intelligent Bit Slaves,
with Industry-standard e-CON connectors.
Slave Units capable of 2-point bit-level distribution.
The I/O power supply is supplied from the communications,
power in the previously connected flat cable, and has a,
short-circuit detection function for protection DRT2-MD32ML.
Industry-standard e-CON connectors.
Short-circuit protection safeguards the network,
from I/O short circuits.
Simple communications connections,
with flat cable and connectors.
Bit-level distribution to support,
essentially any application. Input/Output: Outputs.
Internal I/O circuit common: PNP (+ common).
I/O points: 8 points.
I/O connection method: Sensor connector.
Rated voltage for I/O power supply: 24 VDC.
Eight Waterproof Terminal Models.
Emphasizing Cost Efficiency.
Reduced Labor.
Connection using connectors reduces the lead time,
required for installation. No tools are required for,
connection to a variety of devices.
Reduced Wiring.
Signal line wiring has been reduced so that the,
Terminal can be mounted closer to sensors and,
other devices.
Relay Box not Required.
Environment-resistant, dust-tight, drip-prroof,
construction (IP67) enables direct on-site,
mounting DRT2-MD32ML.
Easier Maintenance.
Significant reductions not only in setup time but also,
maintenance time.
Reduced Space, Improved Operability,
Compact design (160 x 54 mm (W x H)) (88-point models) DRT2-MD32ML.
Settings and connections can be performed using,
the switch and connectors on the front side of the Terminal.
System Configuration.