Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 1.6 dia.
Protective tubing length L: 20 cm.
Lead wire type: Standard.
Lead wire length M: 2m.
A Wide Variety of High-precision.
Temperature Sensors.
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
and also according to the type and shape of the terminal.
Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 1.6 dia.
Protective tubing length L: 15 cm.
Lead wire type: Heat resistive.
Lead wire length M: 2m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E52-CA20AF D=1.6 2M.
Ideal for the thermal input devices of Temperature Controllers
E52-CA20AF D=1.6 2M
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Control output: voltage output (SSR driver).
Auxiliary output: 2 points.
Heating wire breakage, SSR fault detection function: single phase heater detection function E52-CA20AF D=1.6 2M.
Event input: -.
Communication: RS-485.
Terminal shape: screw terminal table type (main unit + terminal unit).
Power supply voltage: AC100 ~ 240V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type.
DIN 85mm * 22 E52-CA20AF D=1.6 2M. 5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication.
The use of communication adapter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately).
With auxiliary output (maximum 2 points), event input (maximum 1 points), the basic function is complete.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm). Size: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase heater detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV E52-CA20AF D=1.6 2M.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can performm flexible contact output E52-CA20AF D=1.6 2M.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.