OMRON
Home >> Products >> OMRON >> Temperature controller >> input device >> E52-CA50AY D=3.2 NETU 4M Temperature Sensor

E52-CA50AY D=3.2 NETU 4M Temperature Sensor

OMRON E52-CA50AY D=3.2 NETU 4M Manual And Instructions
E52-CA50AY D=3.2 NETU 4M datasheetPDF datasheet

OMRON E52-CA50AY D=3.2 NETU 4M Product information and technical parameters:
Brand: OMRON
Name: Temperature Sensor
Model: E52-CA50AY D=3.2 NETU 4M
Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 3.2 dia.
Protective tubing length L: 50cm.
Lead wire type: Heat resistive.
Lead wire length M : 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal.

Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 4.8 dia.
Protective tubing length L: 20cm.
Lead wire type: Standard.
Lead wire length M : 1m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E52-CA50AY D=3.2 NETU 4M.
Ideal for the thermal input devices of Temperature Controllers E52-CA50AY D=3.2 NETU 4M
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V) E52-CA50AY D=3.2 NETU 4M.
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: transfer output (special terminal).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of / E52-CA50AY D=3.2 NETU 4M.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to Setup and Operatioon E52-CA50AY D=3.2 NETU 4M.
A Complete Range of I/O Capacities,
Functions, and Performance.
Handles More Applications.
The white PV display with a height of 15.2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of oonly 60 mm E52-CA50AY D=3.2 NETU 4M.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature,
Controllers to each other.