Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 4.8 dia.
Protective tubing length L: 35 cm.
Lead wire type: Heat resistive.
Lead wire length M : 4m.
A Wide Variety of High-precision.
Temperature Sensors.
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
and also according to the type and shape of the terminal.
Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-232C.
Previous model: Thermocouple input, --;
Resistance thermometer input, -- E52-IC35AY D=4.8 NETU 4M.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance
E52-IC35AY D=4.8 NETU 4M Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks E52-IC35AY D=4.8 NETU 4M.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors E52-IC35AY D=4.8 NETU 4M.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Size: 1/4 DIN 96 × 96 × 78 (W × H × D).
Power supply voltage: 24 VAC/VDC.
Input type: Thermocouple or Resistance thermometer.
Alarm output: 3.
Control output: Relay output.
Functions: Heater burnout, Yes (CT1); Mounting option units, Yes.
Previous model: None.
These Best-selling General,
purpose Temperature Controllers,
Are Now Even Better.
Controllers now available with analog inputs.
Faster sampling at 2250 ms E52-IC35AY D=4.8 NETU 4M.
Transfer output provided for easy output to recorders.
Models available with a loop break alarm (LBA) and,
heater short alarm (HS alarm).
Manual output provided.
Easy setting with 11-segment displays.
New protoocol called Modbus is installed in the,
models with communications E52-IC35AY D=4.8 NETU 4M.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33.