Protective tubing diameter: D = 6.0.
Sleeve diameter Sleeve length: d = 8mm.
tube thickness: 0.6 mm.
Lead wire length: 2m.
A Wide Variety of High-precision.
Temperature Sensors.
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
and also according to the type and shape of the terminal.
Size: 1/8DIN 48 × 96 × 78 (W × H × D).
Power supply voltage: 100 to 240 VAC.
Input type: Analog (Current, Voltage) Input Type.
Control method: Valve Control.
Number of alarms: 2.
Communica- tions function: None.
Event input: 2 points.
A position proportional control model for the E5EZ-PRR series E52-P20AY-1 D=6 2M.
Depth of only 78 mm.
Various temperature inputs (thermocouple, platinum resistance thermometer,
infrared temperature sensor, voltage inputs) and analog inputs (current, voltage),
Makes use of high-visibility LCD, with three lines of 4-digit display,
for simplicity
E52-P20AY-1 D=6 2M
and clarity.
3 lines of display to observe PV/ SV/ MV (valve open percentage),
clearly displaying the state of control (operations) E52-P20AY-1 D=6 2M.
Event input enables multi-SP selection and run/ stop function.
Alarm delay function.
Communications function.
Able to choose closed/floating control. In floating control,
position proportional control can be performed without a potentiometer,
Equipped with a manual output function (equipped with an automatic/manual key),
CE marking and UL/CSA certification. Terminal type: Exposed-lead Models E52-P20AY-1 D=6 2M.
Protective tubing diameter D: 3.2 dia.
Protective tubing length L: 20cm.
Lead wire type: Standard.
Lead wire length M: 2m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-485.
Previous model: Thermocouple input, E5GN-R03TC-FLK;
Resistance thermometer input, E5GN-R03P-FLK.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of thhe Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E52-P20AY-1 D=6 2M.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E52-P20AY-1 D=6 2M.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.