OMRON
Home >> Products >> OMRON >> Temperature controller >> Universal temperature controller >> E5AZ-Q3HMTD Digital Temperature Controllers

E5AZ-Q3HMTD Digital Temperature Controllers

OMRON E5AZ-Q3HMTD Manual And Instructions
E5AZ-Q3HMTD datasheetPDF datasheet
E5AZ-Q3HMTD User's Manual
E5AZ-Q3HMTD Communications Manual

OMRON E5AZ-Q3HMTD Product information and technical parameters:
Brand: OMRON
Name: Digital Temperature Controllers
Model: E5AZ-Q3HMTD
Size: 1/4 DIN 96 × 96 × 78 (W × H × D).
Power supply voltage: 24 VAC/VDC.
Input type: Thermocouple or Resistance thermometer.
Alarm output: 3.
Control output: Voltage output .
Functions: Heater burnout, Yes (CT1); Mounting option units, Yes.
Previous model: None.
These Best-selling General,
purpose Temperature Controllers,
Are Now Even Better.
Controllers now available with analog inputs.
Faster sampling at 250 ms.
Transfer output provided for easy output to recorders.
Models available with a loop break alarm (LBA) and,
heater short alarm (HS alarm).
Manual output provided.
Easy setting with 11-segment displays.
New protocol called Modbus is installed in the,
models with communications.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33.

Size: 96 x 96mm.
Ontology: terminal type, analog input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: relay output.
Control output 2: high life relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use E5AZ-Q3HMTD E5AZ-Q3HMTD
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance E5AZ-Q3HMTD.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc E5AZ-Q3HMTD. , can be a key operation. Programmable Controllers Join the Series!
Program up to 256 segments and take advantage of the high cost performance,
of the new LCD that improves both the field of view and contrast.
Set up to 8 programmed patterns with up to 32 segments (steps) each.
High-resolution display with 5 digits/0.01°C display.
High-speed sampling cycle of 60 ms.
High Accuracy.
Thermocouple/Pt input: ±0.1% of PV,
Analog input: ±0.1% FS,
Universal inputs on all models (thermocouple, PT, or analog,
input) to handle various sensors with one Controller. Models,
also available with Remote SP.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/RESET, and alarms) and the PV or SVV E5AZ-Q3HMTD.
Flexible contact outputs with logic operations (AND, OR, and,
delays) set from the Support Software (CX-Thermo version,
4.3). Program settings can be managed.
An infrared ports enables communications from the front panel.
Preventtive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter E5AZ-Q3HMTD.
Model available with position-proportional control.