Size: 1/4 DIN 96 × 96 × 78 (W × H × D).
Power supply voltage: 100 to 240 VAC.
Input type: Analog (current/voltage).
Alarm output: 3.
Control output: Relay output.
Functions: Heater burnout, Yes (CT1); Mounting option units, Yes.
Previous model: None.
Are Now Even Better.
Controllers now available with analog inputs.
Faster sampling at 250 ms.
Transfer output provided for easy output to recorders.
heater short alarm (HS alarm).
Manual output provided.
Easy setting with 11-segment displays.
models with communications.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33.
Size: E5CSV 48 × 48mm.
Type: Terminal block.
Control modes: ON/OFF or PID.
Alarms: 1.
Outputs: Relay.
Model with platinum resistance thermometer.
Easy Setting Using DIP Switch and Simple.
Functions in DIN 48 × 48 mm-size Temperature.
Controllers.
Easy setting using DIP switch.
Models with two alarms added to Series, ideal for temperature,
alarm applications E5AZ-R3HML.
Universal-input (thermocouple/platinum resistance thermometer),
models also available
E5AZ-R3HML
Clearly visible digital display with character height of 13.5 mm.
Models available with black in addition to white cases.
RoHS compliant. The main body: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V) E5AZ-R3HML.
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade E5AZ-R3HML.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 4.8 dia.
Protective tubing length L: 50 cm.
Lead wire type: Standard.
Lead wire length M : 4m.
A Wide Variety of High-precision.
Temperature Sensors E5AZ-R3HML.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5AZ-R3HML.