With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
The use of communication adapter cable (sold separately) connected with a computer.
Combined temperature control device through component communication.
Element type: J (IC).
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 15 dia.
Protective tubing length L: 100 cm.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5CC-QX3DSM-004.
Ideal for the thermal input devices of Temperature Controllers
E5CC-QX3DSM-004
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V) E5CC-QX3DSM-004.
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of / E5CC-QX3DSM-004.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Name: Temperature Controller (See note 1.).
Power supply: 24 VDC.
No. of control points: 2.
Control output: Voltage output (for SSRs).
Auxiliary output: Transistor output: 2 pts (sinking).
Functions: Heater burnout alarm (See note 3.), Heating or heat/cool,
control is selectable (See note 4.)Event input: 1 point per Unit.
Communications functions: RS-485.
Input type (See note 5.): Thermocouple.
New DIN Track Mounting Temperature.
Controller.
Two channels of temperature control available despite width of,
only 22.5 mm.
The Temperature Controller itself can be replaced wwithout,
changing terminal wiring E5CC-QX3DSM-004.
Use in combination with a compact Setting Display Unit to,
reduce communications programming requirements.
Front-panel LED indicators for easy operation monitoring.
Power supply and communicatiions wiring not required between,
Units when mounted side-by-side E5CC-QX3DSM-004.
CompoWay/F communications protocol supported.
UL, CSA, and CE Marking compliance.