Size: 1/16 DIN.
Case color: Black.
Power supply voltage: 100 to 240 VAC.
Input type: Analog (current/voltage).
Auxiliary outputs: 2.
Control output 1: Voltage output (for driving SSR).
New 48 x 48-mm Basic Temperature.
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
current outputs.
manual, RUN/STOP, and alarms) and the PV or SV.
Controller using a Control Output ON/OFF Counter.
Size: 48 x 96mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 2 independent points.
Power supply voltage: AC/DC24V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: -.
Communication: RS-485 E5CN-Q2LU.
Event input: 4 points.
Remote SP input: there.
Transfer output: have.
Large screen display white PV legible
E5CN-Q2LU From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply E5CN-Q2LU.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications E5CN-Q2LU.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve. Name: End Unit *1.
Power supply voltage: 24 VDC.
No. of control points: None.
Control outputs 1 and 2: None.
Control outputs 3 and 4: None.
Auxiliary output: Transistor output: 2 points (sinking).
Functions: burnout Heater alarm, None; Event inputs, None.
Communications functions: Port A or B: RS-485 Connector: Port A.
Input type: No input.
Terminal: Screw-less clamp.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements.
Connect directtly to the G3ZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise E5CN-Q2LU.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calcullate the PID constants with the step,
response method E5CN-Q2LU.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit.