OMRON
Home >> Products >> OMRON >> Temperature controller >> Universal temperature controller >> E5CZ-Q2TU Digital Temperature Controllers

E5CZ-Q2TU Digital Temperature Controllers

OMRON E5CZ-Q2TU Manual And Instructions
E5CZ-Q2TU datasheetPDF datasheet
E5CZ-Q2TU Communications Manual

OMRON E5CZ-Q2TU Product information and technical parameters:
Brand: OMRON
Name: Digital Temperature Controllers
Model: E5CZ-Q2TU
Size: 1/16 DIN.
Power supply voltage: 100 to 240 VAC.
Input type: Thermocouple or Resistance thermometer.
Alarm output: 2.
Control output: Voltage output (for driving SSR).
Previous mode: None.
This Best-selling General-purpose,
48×48-mm Temperature Controller,
Is Now Even Better.
Controllers now available with analog inputs.
Faster sampling at 250 ms.
Transfer output provided for easy output to recorders.
Models available with a loop break alarm (LBA) and,
heater short alarm (HS alarm).
Easy setting with 11-segment displays.
Setting protection indicator informs operator when,
protection is enabled.
Manual output provided.
New protocol called Modbus is installed in the models,
with communications.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33.

Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard.
Auxiliary output points: -.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use E5CZ-Q2TU.
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade E5CZ-Q2TU
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E5CZ-Q2TU.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Control output 1: Relay output.
Control output 2: --.
Auxiliary output: Three.
Communications: --.
Heater burnout: --.
Event inputs: --.
Power supply voltage: 100 to 240 VAC E5CZ-Q2TU.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to Setup and Operation.
A Complete Range of I/O Capacities,
Functions, and Performance.
Handles More Applications.
The white PV display with a height of 15.2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature,
Controllers to each other. Control output 1: Linear current output.
Control output 2: --.
Auxiliary output: Three.
Communications: --.
Heater burnout: --.
Event inputs: --.
Power supply voltage: 24 VAC/VDC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to Seetup and Operation E5CZ-Q2TU.
A Complete Range of I/O Capacities,
Functions, and Performance.
Handles More Applications.
The white PV display with a height of 15.2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm E5CZ-Q2TU.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature,