OMRON E5EN-C3T-W-N Manual And Instructions
E5EN-C3T-W-N datasheetPDF datasheet
E5EN-C3T-W-N datasheetPDF datasheet
E5EN-C3T-W-N datasheetPDF datasheet
E5EN-C3T-W-N Basic TypeUser's Manual
E5EN-C3T-W-N User's Manual
E5EN-C3T-W-N User's Manual
E5EN-C3T-W-N User's Manual
E5EN-C3T-W-N Communications FunctionsUser's Manual
E5EN-C3T-W-N INSTRUCTION Manual
E5EN-C3T-W-N INSTRUCTION Manual

OMRON E5EN-C3T-W-N Product information and technical parameters:
Brand: OMRON
Name: Foundation type temperature controller
Model: E5EN-C3T-W-N
Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.

Size: 1/16 DIN.
Case color: Black.
Power supply voltage: 24 VAC/VDC.
Input type: Thermocouple or resistance thermometer.
Auxiliary outputs: 2.
Control output 1: Current output.
New 48 x 48-mm Basic Temperature.
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function E5EN-C3T-W-N.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0 E5EN-C3T-W-N5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
New E5CN-U Models (Plug-in Models) with analog inputs and,
current outputs.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5EN-C3T-W-N.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter. Lead wire length: 2m.
Element type: K (CA).
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5EN-C3T-W-N.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Thermocouple type: K (CA).
Heat resistance: General use.
Outer packing: all ethylene outer wrapping (waterproof).
Compensating wire length: 1 m.
A variety of high precision temperature sensor series.
On the basis of the previous M3 screw,
An additional rod like terminal corresponding to the reduced wiring working hours.
A temperature sensor is used as a thermal sensor for a thermostat.
According to the temperature, place, the surrounding environment to be measured.
Products with various shapes, shapes, lengths and terminals.
The main body: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output 1: voltage ooutput (SSR driver) E5EN-C3T-W-N.
Control output 2: voltage output (SSR driver)
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power suppply: single phase heater with detection function E5EN-C3T-W-N.
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded