Size: 1/8 DIN 48 × 96 × 78(W × H × D).
Power supply voltage: 24 VAC/VDC.
Input type: Analog (current/voltage).
Alarm output: 3.
Control output: Voltage output (for driving SSR).
Functions: Heater burnout, Yes (CT1); Mounting option units, Yes.
Previous model: None.
Are Now Even Better.
Controllers now available with analog inputs.
Faster sampling at 250 ms.
Transfer output provided for easy output to recorders.
heater short alarm (HS alarm).
Manual output provided.
Easy setting with 11-segment displays.
models with communications.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33.
Size: 48 x 48mm.
Control output 1: current.
Auxiliary (alarm) output: 3.
Transfer output: -.
Event input: 2.
Communication: RS-485.
Disconnection detection: 1.
Power supply voltage: DC24V/AC24V.
The white PV (current value) with excellent visibility shows the segment to make the confirmation work more easily E5EZ-Q3HMLD.
Eye-catching white + industry''s largest display size
The black and white display and the industry''s largest display size to achieve excellent visibility
E5EZ-Q3HMLD
No matter from which angle or in the natural lighting environment, the dark scene,
Can quickly and accurately confirm the current value.
Displays the current value (PV/ white), the target value (SV/ green) and the progress of the program (PRG, SEG/ yellow) E5EZ-Q3HMLD.
Can be viewed at the same time, there is no need to switch the display, so as to improve the efficiency of operations. Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function E5EZ-Q3HMLD.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-TThermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E5EZ-Q3HMLD.
Through the infrared port can be carried out from the frront of the communication E5EZ-Q3HMLD.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.