A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance.
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal.
The use of electric communication conversion Village (sold separately) connected to the computer after,
It can be easily set by CS-Thermo (sold separately).
Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 4.8 dia.
Protective tubing length L: 35 cm.
Lead wire type: Heat resistive.
Lead wire length M: 2m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5GC-CX2A6M-016.
Ideal for the thermal input devices of Temperature Controllers
E5GC-CX2A6M-016
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 1/8 DIN 48 × 96 × 78(W × H × D).
Power supply voltage: 100 to 240 VAC.
Input type: Thermocouple or Resistance thermometer E5GC-CX2A6M-016.
Alarm output: 3.
Control output: Current output.
Functions: Heater burnout, No; Mounting option units, Yes.
Previous model: E5EZ-C3 + E53-AZM.
These Best-selling General,
purpose Temperature Controllers,
Are Now Even Better.
Controllers now available with analog inputs.
Faster sampling at 250 ms.
Transfer output provided for easy output to recorders.
Models available with a loop break alarm (LBA) and,
heater short alarm (HS alarm) E5GC-CX2A6M-016.
Manual output provided.
Easy setting with 11-segment displays.
New protocol called Modbus is installed in the,
models with communications.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33. Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
SSR fault detection function for heater with broken line: detection function for single phase heater.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to checck the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E5GC-CX2A6M-016.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output E5GC-CX2A6M-016.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.