Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-485.
Resistance thermometer input, --.
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
clamp terminal blocks.
manual, RUN/STOP, and alarms) and the PV or SV.
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 8 dia. . .
Protective tubing length L: 50cm.
Lead wire type: Standard.
Lead wire length M : 1m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5GN-Q103L-FLK.
Ideal for the thermal input devices of Temperature Controllers
E5GN-Q103L-FLK
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 4.8 dia.
Protective tubing length L: 20cm E5GN-Q103L-FLK.
Lead wire type: Standard.
Lead wire length M : 2m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5GN-Q103L-FLK. Size: 48 x 24mm.
Control output 1: voltage output (SSR driver).
Control output 2:--.
Auxiliary output: 2 points.
Power supply voltage: AC100 ~ 240V.
Terminal type: screw terminal table type (with terminal cover).
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: 1 points.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal E5GN-Q103L-FLK.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication converrsion Village (sold separately) connected to the computer after,
No power connection can be set E5GN-Q103L-FLK.
It can be easily set by CS-Thermo (sold separately).