OMRON E5ZN-DRT Product information and technical parameters:
Brand: OMRON
Name: DeviceNet Communications Unit
Model: E5ZN-DRT
Streamlined Communications from.
Temperature Controller to PLC.
The E5ZN Modular Temperature Controller is connected to,
the DeviceNet network.
The I/O link function allows setting and monitoring (e.g., of,
present values) for the E5ZN Modular Temperature Controller to,
be performed without communications programming.
Up to 16 E5ZN Modular Temperature Controllers can be,
connected to one Unit.
All the parameters for the E5ZN can be uploaded or download,
ed in one operation using DeviceNet Configurator.

Size: 48 x 48mm.
Body: terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
SSR fault detection function for heater with broken line: detection function for single phase heater E5ZN-DRT.
Event entry point: 2.
Transfer output: -.
Communication: - E5ZN-DRT
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm) E5ZN-DRT.
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay faultSize: 96 x 96mm E5ZN-DRT.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: ES1B power supply.
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(auutomatic / manual, RUN/STOP, alarm), interactive display PV/SV E5ZN-DRT.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5ZN-DRT.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.


...More relevant models >>>>