Insulation method: Photocoupler.
Operation indicator: Yes.
Response speed: Low-speed.
Applicable load: 4 to 32 VDC 0.1 to 100 mA.
Input rated voltage: 5 VDC.
SSR with Plug-in Terminals.
The Same Shape as the G2R-1-S.
Power Relays.
These I/O solid state relays can be mounted in OMRON.
G70A I/O Terminals.
Modules for standard loads.
(-UTU models).
Name: Short-circuit Unit.
Current flow: 10 A, 20 A.
Applicable SSR: G3PA-210B-VD, G3PA-220B-VD, G3PA-420B-VD.
Refer to Safety Precautions for All Solid State Relays.
Allows 2-wire Switching of 3-phase Power.
Ideal for 2-wire switching of 3-phase heaters.
Improve ease of operation. Terminal (wire connection): Push-In Plus Terminal G3R-IDZR1SN-1 DC5.
Applicable output load: AC load.
Zero cross function: No
G3R-IDZR1SN-1 DC5
Rated input voltage: AC/DC 48V.
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals G3R-IDZR1SN-1 DC5.
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals.).
No screw loosening means maintenance-free application,
realizing high reliability.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires.
Screw terminal is also stocked to meet the screw type needs G3R-IDZR1SN-1 DC5.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange. Isolation: Photocoupler.
Zero cross function: --.
Indicator: NO.
Rated output load: 2 A at 5 to 110 VDC.
Rated input voltage: 4 to 24 VDC.
International Standards for G3F Series,
Same Profile as MY Power Relays.
Shape-compatible with mechanical relays.
Certified by UL, CSA, and VDE (model numbers with a suffix of“-VD”).
Socket type, same size as MY Power Relays.
Operation indicator provided to confirm input.
(model numbers with “N” before the suffix). Number of elements: 3.
Isolation method: Phototriac coupler.
Rated powersupply voltage: 100 to 240 VAC.
Input method: No-voltage input (open and short circuited input).
Applicable monitor capacity (AC3): 3.7 kW (17.4 A), 200 to 220 VAC.
Monitor output: AC switching outputt G3R-IDZR1SN-1 DC5.
New Models with AC Power Supply Input and,
Monitor Output Equivalent to Non-contact,
SPST-NO Join the G3J-T Series,
Limiting the starting current saves energy.
Certified for UL and CSA.
Mounts with screws or to DIN Track.
Compact design with heat sinks (3 G3R-IDZR1SN-1 DC5. 7-kW models: 100 × 100 ×130 mm (W × H × D)).
Built-in snubber circuit and thyristor.
Built-in operation indicator.