OMRON G3RV-SR500-D AC110 Product information and technical parameters:
Brand: OMRON
Name: Slim I/O Relay
Model: G3RV-SR500-D AC110
Terminal (wire connection): Push-In Plus Terminal.
Applicable output load: DC load.
Zero cross function: --.
Rated input voltage: AC 110V.
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals.
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals.).
No screw loosening means maintenance-free application,
realizing high reliability.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange.

Isolation: Photocoupler.
Zero cross function: --.
Indicator: Yes.
Rated output load: 2 A at 5 to 110 VDC.
Rated input voltage: 200/220 VAC.
International Standards for G3F Series,
Same Profile as MY Power Relays.
Shape-compatible with mechanical relays.
Certified by UL, CSA, and VDE (model numbers with a suffix of“-VD”) G3RV-SR500-D AC110.
Socket type, same size as MY Power Relays.
Operation indicator provided to confirm input G3RV-SR500-D AC110
(model numbers with “N” before the suffix). Contact configuration: Four SPST-NO relays.
Heat sink: Yes.
Built-in SSRs: G3SD-Z01P-PD.
Zero cross function: No.
Applicable output load: 1 A at 3 to 26 VDC (See note 2.).
Rated voltage: 5 VDC, 12 VDC, 24 VDC.
Compact Terminal SSR with 4 Outputs G3RV-SR500-D AC110.
Easy-to-use SSR block that combines four compact G3S SSRs,
sockets, and heat sink in one unit.
Easy wiring with separate I/O terminal construction.
LED operation indicator.
Special socket used for easy Relay replacement.
Mounts either on DIN track or with screws. Standard certification: No.
Insulation mode: three end two-way photoelectric switch.
Zero trigger function: No G3RV-SR500-D AC110.
Action indicator: there.
Applicable load of output: AC100 3A ~ 240V.
Input rated voltage: DC12V.
With the LY1, LY2 large power relay with the same shape of the G3H series, the new international standard certification (-VD type).
Achieved UL, CSA, EN (VDE certification) standard certification. (type -VD)
Socket terminal type of same size with LY (1 pole, 2 pole type).
A model with an action indicator to check the status of the input. (type N)Mounting type: W-bracket(see note).
Contact form: 4PST-NO.
Quick-connect terminals.
A High-capacity, High-dielectric-strength,
Multi-pole Relay Used Like a Contactor.
Miniature hinge for maximum switching power forr motor loads,
as well as resistive and inductive loads G3RV-SR500-D AC110.
No contact chattering for momentary voltage drops up to 50%,
of rated voltage.
Withstanding more than 4 kV between contacts that are differ,
ent in polarity and betweenn the coil and contacts G3RV-SR500-D AC110.
Flame-resistant materials (UL94V-0-qualifying) used for all in,
sulation material.
Standard models approved by UL and CSA.