OMRON
Home >> Products >> OMRON >> Relay >> General relay >> Built in power relay >> G7Z-2A2B-11Z Power Relays

G7Z-2A2B-11Z Power Relays

OMRON G7Z-2A2B-11Z Manual And Instructions
G7Z-2A2B-11Z datasheetPDF datasheet

OMRON G7Z-2A2B-11Z Product information and technical parameters:
Brand: OMRON
Name: Power Relays
Model: G7Z-2A2B-11Z
Classification: Relay with Auxiliary Contact Block.
Structure: 4 poles + 2 poles.
Contact configuration: Relay, DPST-NO/DPST-NC; Auxiliary Contact Block, SPST-NO/SPST-NC.
Rated Voltage: 12, 24 VDC.
Compact Electromagnetic Contactors That.
Switch 40 A at 440 VAC.
One pole carries 40 A.
UL 508 and UL 840 NC contacts (resistive 40 A 480 VAC, 60 Hz, 80,000 operations).
EN 60947-4-1 NC contacts (AC1 40 A 440 VAC, 50/60 Hz, 80,000 operations).
Ideal for supply power to industrial inverters, servo drivers, and other devices,
and switching power to motors and other equipment.
The maximum load capacity of 160 A when using 4-pole parallel connections.
EN 60947-4-1 certification for mirror contact mechanism obtained by combining,
the Relay with an Auxiliary Contact Block.
Conforms to European PV standard (VDE0126).
Approx. 30% less operation noise than a standard electromagnetic contactor.
(Approx. 100 dB reduced to approx. 70 dB.)
Approx. 50% the volume of a standard electromagnetic contactor,
to help downsize control panels.
According to OMRON investigation of IIEC-AC1 50 A specifications.

Classification: Models with built-in diodes.
Rated voltage: Standard products, 24 VDC;
Made-to-order items, 12 or 100/110 VDC.
New Latching Levers for Circuit Checking.
Added to Our Best-selling.
MY General-purpose Relays.
Now lead-free to protect the environment.
VDE certification (Germany).
Different colors of coil tape for AC and,
DC models to more easily distinguish them G7Z-2A2B-11Z.
MY(S) models with latching levers added for,
easier circuit checking G7Z-2A2B-11Z Insulation method: Photocoupler.
Operation indicator: Yes.
Zero cross function: --.
Applicable load: 2 A at 5 to 48 VDC.
Input rated voltage: 5 to 24 VDC.
SSR with Plug-in Terminals.
The Same Shape as the G2R-1-S.
Power Relays.
These I/O solid state relays can be mounted in OMRON G7Z-2A2B-11Z.
G70A I/O Terminals.
Lineup includes Input Modules for microloads and Output,
Modules for standard loads.
Lineup also includes UL, CSA, and TÜV-certified models,
(-UTU models). Construction: insert / solder terminal.
Contact form: 3PDT.
Indicator: led.
Note: when the order is ordered, the number of the models is added with the rated voltage of the coil G7Z-2A2B-11Z.
For example: DC12 DC12, LY1-J on behalf of the rated voltage of the coil.
Arc barrier equipped with high insulation strength (AC2000V). Number of elements: 3.
Isolation method: Phototriac coupler.
Rated powersupply voltage: 12 to 24 VDC.
Input method: No-voltage input (open and short circuited input).
Applicable monitor capacity (AC3): 0.75 kW (4.8 A), 200 to 220 VAC.
Monitor output: DC switching output.
New Models with AC Power Supply Input and,
Monitor Output Equivalent to Non-contact,
SPST-NO Join the G3J-T Series,
Limiting the starting current saves energy.
Certified for UL and CSA.
Mounts with screws or to DIN Track.
Compact design with heat sinks (3.7-kW models: 100 × 100 ×130 mm (W × H × D)).
Built-in snubber circuit and thyristor.
Built-in operation indicator. Number of elements: 3.
Isolation method: Phototriac coupler.
Rated powersupply voltage: 12 to 24 VDC.
Input method: No-voltage input (open and short circuited input).
Applicable monitor capacity (AC3): 3.7 kW (17.4 A), 200 to 220 VAC.
Monitor output: DC switching ooutput G7Z-2A2B-11Z.
New Models with AC Power Supply Input and,
Monitor Output Equivalent to Non-contact,
SPST-NO Join the G3J-T Series,
Limiting the starting current saves energy.
Certified for UL and CSA.
Mounts with screws or to DIN Track.

Compact design with heat sinks (3 G7Z-2A2B-11Z. 7-kW models: 100 × 100 ×130 mm (W × H × D)).
Built-in snubber circuit and thyristor.
Built-in operation indicator.


...More relevant models >>>>