Name: Slice I/O Units; Digital I/O Units.
Specifications: AC Input 4 points.
Standards: CE, UC1, L.
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
wiring in the system.
contribute to system size reduction.
helps to detect errors on site.
content of the error.
Short/disconnection detection: Supported.
Specifications: Outputs, PNP (+ common), 32 points.
I/O connections: Clamp terminals.
Rated internal circuit power supply voltage:
Supplied from communications connector.
Rated I/O power supply voltage: 24 VDC.
Reduced Wiring and Labor on Factory Sites with Screw-less Terminal Wiring GRT1-IA4-2.
Screw-less structure eliminates tightening work.
Detachable terminal blocks for easier maintenance
GRT1-IA4-2
Single-step wiring by simply inserting pole terminals. Classification: Analog Input Terminal.
I/O points: 1 to 4 (selectable with DIP switch).
Compact Analog Input Model is the,
Same Shape as 16-point Remote I/O Terminals.
Allows flexible input point settings up to a maximum of four points GRT1-IA4-2.
Resolution: 1/6,000.
Takes only 1 ms to exchange each input point.
Wide input ranges available.
105 x 48 x 50 (W x H x D). Specifications: Relay output; 16 points.
I/O connections: M3 terminal block.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
I/O power supply voltage: Supplied from,
communications connector GRT1-IA4-2.
A Smart Slave with Relay Outputs and One-step,
Relay Replacement for Remote Maintenance.
Capable of handling large-capacity output,
devices (3 A max.) Easy relay replacement. Name: Temperature Input Units.
Specifications: Platinum-resistance,
thermometer input; 4 inputs;
PT100 (-200 to 850°C),
PT100 (-200 to 2000°C).
Standards: CE, UC, UC1, N .
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Internal I/O common: PNP.
I/O indicators: LED display (yellow).
Unit power supply current consumption: 120 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 140 g max.
Expansion functions: No.
Short-circuit protection function: Available at input,
section only (Operates at 50 mA/point min.)
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors.
A common terminal is provided for,
each connector GRT1-IA4-2.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
sswitch and with tool software GRT1-IA4-2.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.