OMRON H3CR-FN Manual And Instructions
H3CR-FN datasheetPDF datasheet
H3CR-FN INSTRUCTION MANUAL

OMRON H3CR-FN Product information and technical parameters:
Brand: OMRON
Name: Solid-state Twin Timers
Model: H3CR-FN
Operating modes: Flicker ON start.
Supply voltage: 100 to 240 VAC/100 to 125 VDC, 24 to 48 VAC/12 to 48 VDC.
0.05 s to 300 h models: 11-pin models.
DIN 48 × 48-mm Twin Timers.
Wide power supply ranges of High Voltage 100 to 240 VAC/100,
to 125 VDC and Low Voltage 24 to 48 VAC/12 to 48 VDC.
ON- and OFF-times can be set independently and so,
combinations of long ON- or OFF-time and short OFF- or ON,
time settings are possible.
Twenty-four time ranges from 0.05 s to 300 h depending on the,
model to be used.
Models with a flicker ON start or flicker OFF start are available.
Easy sequence checks through instantaneous outputs for a,
zero set value at any time range.
Length, when panel-mounted with a Socket, of 80 mm or less.
11-pin and 8-pin models are available.

Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
No output: -.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table H3CR-FN.
Action determine the color, can switch the green / Red 2 kinds of color display H3CR-FN
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, the maximum measurable range from 10ms to 3200s.
6 measurement methods,Input type: PNP input type H3CR-FN.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Transistor: -; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table.
Action determine the color, can switch the green / Red 2 kinds of color display H3CR-FN.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, the maximum can be measured from 10Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Communication: RS-485; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth H3CR-FN.
Power supply voltage: AC100 ~ 240V.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time H3CR-FN.
Measuring, calculating and displaying the pulse interval between 2 points.
Range of pulse interval measurement,


...More relevant models >>>>