Specify the operation days.
Up to 12 ON/OFF operations (24 for pulse-output operation).
setting function.
ily using output override and automatic return operation.
The operation program can be checked easily with the program check function.
Enables pulse output operation and summer time setting.
Incorporates finger-safe terminals.
Conforms to UL, CSA, and CE marking.
surface mounting, and DIN track mounting.
Input type: PNP input type.
Event input terminal 5 points (S-TMR, HOLD, RESET) is equipped with.
External power 80mA DC12V.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Communication: RS-232C; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V H5F Series.
Digital rotating pulse meter with high speed measurement for 50kHz
H5F Series
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of 50kHz high speed pulse.
Can rotate the encoder and a variety of ON/OFF pulse signal, up to 50kHCount input: No-voltage input.
Display: 7-segment LCD.
Max. revolutions displayed (applicable encoder resolution):
1000 s–1 (1 pulse/rev H5F Series. ), 1000 min–1 (60 pulse/rev.); Light-gray body.
Revolutions displayed up to five digits.
Dual revolution display according to encoder resolution used;
1000 s–1/1000 min–1 or 1000.0 s–1 /1000.0 min–1,
Switchable dual revolution display type available (-NV1 models);
extended up to 10000 min–1. Input: With reset input.
Output: SPDT.
Supply voltage: 100 to 120 VAC, 200 to 240 VAC, 24 VAC/DC, 48 VDC, 100 to 125 VDC H5F Series.
8-pin models: S-series, M-series.
DIN 48 X 48-mm Power OFF-delay Timer.
Long power OFF-delay times;
S-series: up to 12 seconds,
M-series: up to 12 minutes.
Models with forced-reset input are available.
11-pin and 8-pin models are available. Timer input: PNP/NPN universal DC voltage input(4.5 to 30 VDC).
Display: 7-segment LCD.
Time range: 999999.9h ←→ 3999d23.9h(switchable); Light-gray body.
Seven digits, time range 0 to 3999d23.9h.
Dual time range: 999999.9 ←→ 3999d23.9h or,
999h59m59s ←→ 9999h59.9m. Category: external supply 100mA DC10V.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Relay contact: HH; PASS1c, H, L, LL: each 1a.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified H5F Series.
Action determine the color, can switch the green / Red 22 kinds of color display H5F Series.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of