OMRON
Home >> Products >> OMRON >> Power/other peripheral devices >> Power / equipment protection equipment >> Distributed power supply >> K2ZC-K2FA-N Composite relay for the connection of a distributed power supply system

K2ZC-K2FA-N Composite relay for the connection of a distributed power supply system


OMRON K2ZC-K2FA-N Product information and technical parameters:
Brand: OMRON
Name: Composite relay for the connection of a distributed power supply system
Model: K2ZC-K2FA-N
Model: OFR (95H).
Protection of distributed power supply connection to power system,
The relay is smaller, and the protection unit is more enriched.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular.
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system.
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system.
Can also correspond to the generator and the electric side / internal tributaries.
Unit with 2 relay elements.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determine the direction of the sudden drop in the voltage to 0 of the short-circuit accident.
2 stage cross terminal stand with cover with convenient wiring.

Power supply (commercial AC power supply) power cut detector for monitoring and control device.
Instantaneous detection voltage drop, power failure, instantaneous power failure.
Small, easy to install DIN guide rail mounting type.
Input voltage is divided into AC100V, AC200V two specifications. Time specification: Instantaneous type K2ZC-K2FA-N.
Current setting range: 2 to 8 A.
Operating voltage: 200/220/240 VAC K2ZC-K2FA-N
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase K2ZC-K2FA-N.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K2ZC-K2FA-N. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Appearance: square shell embedded F1.
Static type reverse electric relay K2WR type.
Reverse power relay for household and marine generator.
A high precision power detection can be performed by the analog time division multiplier.
Through the rated voltage of the switch, adjust the current simulation of variable,
Can correspond to the rated value of all generators.
Due to the instant start in contact, the response difference is minimal,
Position detection with high acccuracy K2ZC-K2FA-N. Sharing with voltage input, no need to control the power supply.
Because it is static, so the anti vibration impact ability, action stability.
Equipped with easy to manage and maintain the boot display with LED. Type: Normal wirring K2ZC-K2FA-N.
Cable length L: 2.0 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch.