OMRON
Home >> Products >> OMRON >> Control equipments >> Digital panel table >> Pulse input >> K3HB-PPB-L2AT11 AC/DC24V Time interval table

K3HB-PPB-L2AT11 AC/DC24V Time interval table

OMRON K3HB-PPB-L2AT11 AC/DC24V Manual And Instructions
K3HB-PPB-L2AT11 AC/DC24V datasheetPDF datasheet

OMRON K3HB-PPB-L2AT11 AC/DC24V Product information and technical parameters:
Brand: OMRON
Name: Time interval table
Model: K3HB-PPB-L2AT11 AC/DC24V
Input type: PNP input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Linearity: voltage; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, the maximum can be measured from 10ms to

Wiring: Screw terminals.
Mounting method: Surface mounting/track mounting.
Daily Time Control with Simple Operations,
Specify the operation days.
(However, you can set only one pattern of operation days,
and specified days.)
Up to 12 ON/OFF operations (24 for pulse-output operation).
Special holidays can be handled easily with the holiday,
setting function K3HB-PPB-L2AT11 AC/DC24V.
Adjustments for sudden schedule changes can be made eas,
ily using output override and automatic return operation K3HB-PPB-L2AT11 AC/DC24V
The operation program can be checked easily with the program check function.
Enables pulse output operation and summer time setting.
Incorporates finger-safe terminals.
Conforms to UL, CSA, and CE marking.
Meets a variety of mounting requirements: flush mounting,
surface mounting, and DIN track mounting K3HB-PPB-L2AT11 AC/DC24V. Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET, COMPENSATION) is equipped with.
External power supply DC12V80mA.
Communication: RS-232C; NPN open collector (OUT5, OUT4, OUT3, OUT2, OUT1).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
High speed pulse K3HB-PPB-L2AT11 AC/DC24V.
Measuring, increasing or decreasing pulse meter.
Action determine the color, can switch the green / Red 2 kinds of color display.
The best choice of rotating encoder and all kinds of ON/OFF pulse signal at high speed,
Cumulative pulse input is 50kHz, phase difference pulse is 25kHz, increase or decreaseInput type: DC voltage input type.
Output type: communication; RS-485; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with.
Thee most suitable voltage and current signal simulation, measurement and display, identification of the panel table K3HB-PPB-L2AT11 AC/DC24V.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub presssure gauge for monitoring the operation trend K3HB-PPB-L2AT11 AC/DC24V.
External event input can be applied to a variety of measurement and identification situations.
DeviceN


...More relevant models >>>>